Troubleshooting Guides; Troubleshooting Guides. Breakers do wear out, especially if used often as the pump switch. Turn it off fully, then back on again. Thats either gears not engaged, or stuck or its a dead motor (timer motor). What is the problem. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. One washer on each side of the spring, you are correct. If all is well then 99% sure it would be the capacitor, weak and needs replacement. If the control exceeds the maximum number of ignition retries or recycles the heater will shut down and go into lockout. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. I remplace it and now the sistem works!! All-In-One Sanitization I am a new pool owner and first Hayward pump. When I turn on my clock and put my ear close to the clock I hear the clock sound like its on but my Hayward filter does not turn on and makes no noise. Please help. Hi Don, when its not an air leak, pump surging will then be an obstruction in the pipe, or filter, heater, check valve/filter valve/diverter valve, a bit of plastic usually (once I found a golf ball, in the skimmer pipe), that is pulled into a 90 or up against a port that is too small for the obstruction to pass. My pump seems to trip the GFCI breaker each time it is plugged in. Third, is there a valve closed after the filter, or some other obstruction? That is usually what causes the rattle. Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. Do you think my pump is gone or is it just needing more water to achieve prime again? Products, learn The motor model # is C48L2N134B1. Big difference, but other than that, they operate pretty much the same! Hi, I have a hayword C48L2N134B3 1.5 HP pool pump. You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. For pools up to 40,000 gallons. It feels like its not doing what its supposed to do. Poseer una casa es la piedra angular de la riqueza tanto la riqueza financiera como la seguridad emocional. Sometimes pump lids can also warp or even the pump housing or internals, in cases where the pump got REALLY hot, but that is rare, but if the cause, youd need some new parts, or new pump. I may have purchased a defective pump?? 4. leaky valve or unions in front of pump FYI I moved the voltage selector to 115. "@type": "ImageObject",
When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. Hi Sean, the Powerflo pump lid has a very tight seal, likely the o-ring needs to be removed, cleaned off with a rag, replaced and lubed with a Teflon lubricant like Magic lube or other Pool Lube. Hi we have a Hayward DE filter for a 2040 in ground. Is my pool pump dead? For the leaking underneath, that sounds like the shaft seal SPX1600Z2 or it could be leaking around the plumbing fitting threads, where water exits the pump, and is running down the side of the pump and dripping off the bottom. The board wasnt showing anything. Could the water have damaged the motor ? HI Sang, check the capacitor, or just replace it, they are cheap, it is the large black cylinder at 9 oclock in the rear of the motor. Strange things that when I have a storm it doesnt break but I does a day after when day is perfect. Does it really need to be replaced? Hi Julie, is the FLO error code on the heater? Step 3: Double check the wires on the flow switch for damage. Troubleshooting a Hayward Aqua Rite can be quick and simple. heard a click at the plug. any advise would be appreciated . This just started. What happens when you switch the output to super-chlorinate? how to watch past broadcasts on twitch. "url": "https://blog.intheswim.com/"
Air leaks can occur over time, the most often areas are a loose pump lid, unlubed pump lid oring, or my favorite, the loose threaded fitting that brings water into the pump. Like it is locked up. On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. Possibly an obstruction on the return line, after the filter? After the pump and filter are fully drained, screw the plugs back in slightly to keep bugs out, but leave them loose so they will still drain, as needed. I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. Reconnect the pipes and test it out! Reset the average salt level on startup and whenever you replace your cell. Factory Direct Pricing Whichever brand they go with, we know that our customers are always looking to get the best price. Pool pump already went out a few months ago. Thanks for your insight. I have a Hayward super pump 1HP. An error was detected in the ignition control circuit board. Has more of an impeller type sound. I opened the back and was spinning the rod and it eventually started. old. The pump stopped priming and allowed water to just flow through but not pressurize the closed filter basket part that is right before the pumpso it looks like a waterfall in the basket flowing from the pipe coming from the pool to the lower end going into the filter. Hi John, the cap for that motor is START CAPACITOR, 161-193 MFD (BC-161) we dont carry it, but easily found online. I have a perflex ec50 that is about four years old. Ship Weight (lbs) : 24.10 Any suggestions? No matter what setting I put it in its backwashing the sand into the skimmer. The small filter, usually at the wall? 9-17-2020 "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
I just purchased a new pump for my pool. Usually get 3-4x that long. http://www.inyopools.com/blogSHOP at our online store! I removed it from the pump housing to troubleshoot it was pumping weakly before stopping. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Look for any small drips or oozing around the filter, or you may be able to hear a small hiss, when the pump shuts off. If flushing and draining does not help, it is time to open up the filter tank, remove the grid assy (or flex tube nest), and after cleaning very well with a hose, soak it in a DE filter cleaner solution (5-gal bucket works well for Perflex). Ive waited a few hours and tried again but no luck. Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. Could be a problem with the centrifugal switch, located dead center on the rear of the motor, or the stationary switch, located beneath it, and contacting each other in the center. Troubleshooting a Salt Chlorinator First, check power. 2. pump lid gasket or o-ring not lubed, or not positioned properly (superpump) Also, make sure you plug in the cell all the way. 2) loose pipe coming into the pump (no sealant, or overheated and slightly shrunk), 3) Loose valve lids or o-rings, air-leaky valves in front of the pump (main drain, skimmer). As to the filter, pool filters need to be matched to the flow rate of the pump. so.it shut off again. It could also be something loose inside of the tank. the 4th wire, the high speed wire. Im very new to pools & pool maintenance in general. I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. Morning , everything was working fine with my Hayward pump. Pump Surging also occurs from low water level, or air leaks in front of the pump. Hi Ray, NOW you may have a bad capacitor. We just opened our pool up cleaned everything out put new D.E. This is common maintenance for any pool Troubleshooting Your Hayward Aqua Rite System, Copyright 2020 INYOpools All rights reserved. The early revisions dont work with the TCELL5 or TCELL9. They have to stick out about 1/8 wider than the plunger disk. Theory and practice | Find, read and cite all the research you need on ResearchGate Chapter 1: The Evil Emperor's Son. I would inspect it for corrosion, wire tightness, water damage or insect damage. Hello, Just bought a house with a pool in January. Lube Gasket (after cleaning, with a rag lube with Teflon or Silicone based pool lube) and 3. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. When we turn on power, the pump does not make noise but the timer box and the circuit box make a light humming noise and then the circuit tripped. It would be best to not abandon the pipe if possible, best for water quality, clarity and turnover rates but sometimes thats not feasible so either way will work! GFCIs are sensitive, but for a reason. Call Hayward and speak to their tech support people, for more precise advice. Also inspect other wires in the back, look for any pinched wires, or wires touching each other. Old pump ran on 120v and ran just fine till we broke it. Sometimes you can pull out the clog with needle nose pliers. Might wait to see if Hayward can give you an answer and probably want to contact the vendor who sold you the pump, which Hayward may require anyway? It could also be the centrifugal switch located in the rear of the motor, on the end of the shaft, check for looseness, broken spring or other damage. All my piping is under concrete and will be very expensive to dig up. Hi We just bought a new Hayward Powerflo Matrix pump and filter. They just reopened my pool. Everything coming in appears to be tight. I backwash and rinse and start again but it does the same thing. The GFI doesnt break which is where the pump is plugged into, it is just the breaker on the eletrical box that pops. They are higher voltage or whateverbut could that be the problem? We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. I never had this problem before. If I block the outflow from it, it stops clicking on and off, and runs smoothly. I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. "height": "219",
SOme pumps have an open bracket where you can see the shaft, but not Hayward. Do you know what would cause this? Also, if there is a GFCI outlet connected, perhaps it is tripped? Our pump wont start at all after opening the pool. I also made sure that the board was changed from T9 to T3 cell. Why is this happening? When I turn the pump on, the Thicker hose Between the pump and sand filter pops out of the end that is connected to the filter. Too much air usually just gets pushed through the filter and back to the pool, or the pump will lose prime if there really is too much air. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. Nothing seems to give it juice. If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). It could be dead. This past week the motor sometimes starts sometimes does not sometimes starts and turns itself off. I have a new pump and brand new grid inside my filter i have no leaks after about 10 minutes my jets stop i back wash filter and it works for about 10 min again i am stumped. Make sure that there are no blockages in the impeller because the motor will not turn if the impeller cannot rotate. This year I have developed a leak under the pump housing I believe. Shock the pool first and overfilter, before pulling pump. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Fixing this issue can be tricky, so we suggest you get the help of a certified professional. If you download the owners manual on the Ecostar there is some further information about Drive Errors, and some things you can try, in the troubleshooting section, to verify the fault, and also lists the part number for the drive, if needed. No need to look for a solution after the impeller, its always before, on the suction side. I have a pump that wants to stop pumping water after a few minutes the flow gets very low. Inspect the motor for any burns evident on the casing as many times, an overheating motor will be shorted across the windings, and will soon fail. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. likely not a fan or impeller problem, because at 3500 RPM (or less), it would wear down anything broken in just a few minutes. Test the capacitor for voltage, or just replace with exact MFD no. Not too bad of a repair, if you want to attempt yourself. Thanks for the comment! When I touch any other speed button, nothing happens. The problem lies, where the power dies as they say. Remove the filter cartridge to see if it continues. For AquaRite, move the switch from auto to off and check all of the readings. Troubleshooting pool heaters is a methodical process, or a process of elimination. Impeller replacement is only ever really needed for breakage or other severe damage, so if it aint broke. Never had an issue with the other motors we have had. Yes, pool heaters do have a minimum flow requirement. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. Hi Shannon, the bolts are spinning. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. Thanks! Any ideas how to address this? There are pegs all around that prevent moving the wrench beyond 11 and 12 oclock and because the shaft only has two flat sides we cannot get the wrench from another angle plus there are other pegs. I would appreciate any kind of trouble shooting and support. What happens if too much air gets in before the high speed kicks in? Also check that the clips and o-rings on the SS bump shaft are all in place.